Product Overview

The Fluke 117 is a compact, true-RMS digital multimeter designed for electricians, featuring non-contact voltage detection, Auto Volts, and LoZ functions to prevent ghost voltage issues.
The Fluke 117 is a compact, true-RMS digital multimeter designed for electricians, offering non-contact voltage detection, Auto Volts, and LoZ functions. It features a 6000-count display, CAT III 600V safety certification, and is ideal for commercial settings. Its rugged design and advanced functions make it a reliable tool for electrical troubleshooting and measurements.

1.2 Key Features and Benefits

The Fluke 117 offers non-contact voltage detection, Auto Volts for automatic AC/DC voltage selection, and LoZ to prevent false readings. It includes a 10A current range, frequency measurement, and a backlit display for visibility. Its CAT III 600V rating ensures safety, while the True-RMS technology provides accurate measurements for reliable troubleshooting.

1.3 Target Audience and Applications

The Fluke 117 is ideal for commercial and residential electricians, offering precise measurements for electrical systems. It’s suitable for hospitals, schools, and industrial settings, ensuring efficiency in troubleshooting and maintenance. Its portability and advanced features make it a reliable tool for professionals needing accurate and safe electrical measurements in demanding environments.

Safety Information

The Fluke 117 meets CAT III 600V safety standards, ensuring protection against electrical hazards. Users must follow all precautions to avoid shock or injury, adhering strictly to guidelines provided in the manual for safe operation and maintenance.

2.1 Safety Precautions and Warnings

Always use the Fluke 117 as specified in the manual to avoid electric shock or injury. Ensure proper terminal connections and range selections. Never bypass safety features or use damaged leads. Verify operation with known voltages and maintain equipment integrity. Adherence to CAT III 600V standards is crucial for user protection during measurements. Proper usage guidelines must be followed strictly.

2.2 Compliance with International Standards

The Fluke 117 meets rigorous international safety standards, including CAT III IEC 61010-1 2nd Edition. This ensures safe operation in demanding environments, adhering to global certifications. Compliance with these standards guarantees reliability and protection for users, aligning with industry best practices for electrical measurement tools. Always rely on certified devices for enhanced safety.

2.3 Proper Usage Guidelines

Always use the Fluke 117 as specified in its manual. Verify operation with a known voltage source before use. Ensure correct terminals and range selection for measurements. Avoid overload conditions and use appropriate test leads. Adhere to safety standards to prevent electrical hazards and ensure accurate readings.

Key Functions and Capabilities

The Fluke 117 features non-contact voltage detection, Auto Volts, and LoZ functions, ensuring accurate measurements. Its true-RMS capability and 6000-count display provide precise readings in various electrical applications.

3.1 Non-Contact Voltage Detection

The Fluke 117 includes VoltAlert technology for non-contact voltage detection, ensuring safe and efficient testing. This feature alerts users to the presence of live voltage without requiring physical contact, enhancing safety in electrical troubleshooting and maintenance tasks. It is particularly useful for identifying potential hazards in commercial and industrial settings.

3.2 Auto Volts and LoZ Functions

The Fluke 117 features Auto Volts, automatically detecting AC or DC voltage, and LoZ (Low Impedance) mode, which prevents false readings from ghost voltage. These functions enhance accuracy and efficiency in electrical measurements, reducing errors caused by cross-wiring or induced voltages, ensuring reliable results in various testing scenarios.

3;3 True-RMS Measurement

The Fluke 117 incorporates True-RMS technology for accurate measurement of distorted waveforms, ensuring precise readings in environments with electrical noise or complex signal patterns. This capability is essential for electricians needing reliable current and voltage measurements in demanding industrial and commercial settings.

Measurement Functions

The Fluke 117 offers versatile measurement functions, including voltage, current, resistance, and continuity testing, along with frequency measurement in select models, ensuring comprehensive electrical troubleshooting capabilities.

4.1 Voltage Measurement (AC/DC)

The Fluke 117 provides accurate AC and DC voltage measurements, with automatic selection between modes to streamline workflows. Its high-resolution display ensures precise readings, while the LoZ function prevents false measurements caused by ghost voltages, making it ideal for various electrical testing scenarios.

4.2 Current Measurement (10 Amp Range)

The Fluke 117 offers a 10 Amp current range, ideal for high-current applications. It ensures accurate and safe measurements with its robust design, suitable for electricians working in commercial and industrial settings. The multimeter’s display provides clear readings, enhancing efficiency in electrical troubleshooting and maintenance tasks.

4.3 Resistance and Continuity Testing

The Fluke 117 includes a resistance measurement function with a range of 600 Ω to 6 kΩ, providing accurate readings. It features an audible continuity test for quick circuit checks. Designed for electricians, it ensures precise and efficient troubleshooting in industrial and commercial environments with clear display and automatic ranging.

4.4 Frequency Measurement (115 & 117 Models)

The Fluke 117 model offers frequency measurement capabilities, ideal for diagnosing electrical systems. It accurately measures frequency from 1 Hz to 10 kHz, ensuring precise analysis of AC signals. This feature is essential for troubleshooting in industrial and commercial settings, providing reliable data for maintenance and repair tasks efficiently.

Display and Controls

The Fluke 117 features a 6000-count LCD display with clear symbols and indicators. Intuitive controls enable easy function and range selection, ensuring precise measurements and user-friendly operation.

5.1 Understanding the Display Layout

The Fluke 117’s display is organized to show measurements clearly. The main numerical value is prominently displayed, with indicators for units, modes, and warnings. Icons like VoltAlert and Continuity modes appear at the top, while error codes and range information are shown below, ensuring quick comprehension for efficient troubleshooting and accurate readings.

5.2 Function and Range Selection

The Fluke 117 uses a rotary switch to select functions like Voltage, Current, Resistance, and Frequency. The Auto Volts feature automatically detects AC or DC voltage. For Resistance, use the manual range button to adjust sensitivity. The multimeter complies with CAT III 600V safety standards, ensuring reliable and secure measurements.

5.3 Special Indicators and Symbols

The Fluke 117 display uses specific symbols to indicate operating modes. The “A w” symbol appears during non-contact voltage detection. “B s” indicates continuity testing, while “C R” signals diode test mode. An “X” warns of unsafe voltage, and “OL” signifies an overload condition. These indicators ensure clear and safe operation.

Calibration and Maintenance

Regular calibration ensures accuracy, while proper battery maintenance and storage prolong the multimeter’s lifespan. Follow guidelines to maintain performance and reliability.

6.1 Calibration Process

The Fluke 117 calibration process involves verifying accuracy and adjusting settings as needed. Users should refer to the manual for step-by-step instructions. Regular calibration ensures precise measurements and compliance with safety standards. Always use authorized Fluke calibration tools and follow guidelines to maintain reliability and performance. Proper calibration is essential for accurate results.

6.2 Battery Maintenance and Replacement

The Fluke 117 uses rechargeable batteries that require proper maintenance. Replace batteries when they show signs of drained power. Use only Fluke-approved replacements to ensure optimal performance. Regularly check battery health and store them in a cool, dry place. Replace every 5 years or as indicated by the manual. Always follow safety guidelines.

6.3 General Care and Storage

To maintain the Fluke 117’s performance, store it in a protective case, away from direct sunlight and moisture. Avoid extreme temperatures and physical stress. Clean the multimeter with a soft cloth and avoid harsh chemicals. Store the device in a dry, cool environment when not in use to prolong its lifespan and accuracy.

Troubleshooting Common Issues

The Fluke 117’s troubleshooting involves addressing error codes, resolving measurement inaccuracies, and managing battery drain issues to ensure optimal performance and reliability in various electrical testing scenarios.

7.1 Error Codes and Solutions

The Fluke 117 displays error codes like OL for overload or OPEN for open circuits. Solutions include checking connections, restarting the meter, or replacing batteries. Refer to the manual for specific code resolutions to ensure accurate measurements and optimal device performance.

7.2 Resolving Measurement Inaccuracies

Inaccuracies may occur due to incorrect range selection or improper probe connections. Ensure connections are clean and secure. Verify the meter is set to the correct function and range. Calibrate the multimeter if necessary, and use the appropriate terminals for measurements. Consult the manual for detailed troubleshooting procedures.

7.3 Addressing Battery Drain Issues

Battery drain can occur due to prolonged use or forgotten Auto Power Off. Regularly check battery life and replace with high-quality batteries. Disable unused features and ensure Auto Off is enabled. Store the multimeter properly when not in use to preserve battery health and longevity.

Accessories and Compatibility

The Fluke 117 comes with TL75 test leads, a holster, and a user manual. It is compatible with optional accessories like additional probes and Fluke Connect.

8.1 Included Accessories (Leads, Holster, etc.)

The Fluke 117 includes a set of 4 mm silicone test leads, a protective holster, and a comprehensive user manual. These accessories ensure safe and convenient operation, with the holster providing easy storage and the leads designed for durability and precise measurements.

8.2 Optional Accessories and Upgrades

Optional accessories for the Fluke 117 include additional test lead sets, such as the TL75, and compatibility with other Fluke products enhances functionality. Upgrades like extended warranty and calibration services are also available, ensuring the multimeter remains accurate and reliable for advanced electrical testing and measurement needs.

8.3 Compatibility with Other Fluke Products

The Fluke 117 is compatible with other Fluke products, enhancing its functionality. It integrates seamlessly with Fluke Connect, enabling data sharing and collaboration. Compatibility with Fluke test leads and accessories ensures versatility, while its design aligns with other Fluke tools for efficient use in professional electrical environments.

Warranty and Support

The Fluke 117 is backed by a three-year limited warranty, ensuring reliability and performance. Fluke offers comprehensive support, including online resources, updates, and expert assistance through their official website.

9.1 Warranty Terms and Conditions

The Fluke 117 multimeter is covered by a three-year limited warranty from the date of purchase, ensuring defect-free material and workmanship. The warranty excludes damages from misuse or unauthorized repairs. For detailed terms, refer to the official Fluke website or contact their customer support team for assistance and clarification.

9.2 Contacting Fluke Support

For assistance, contact Fluke support at 1-888-99-FLUKE (USA), 1-800-36-FLUKE (Canada), or 31 402-675-200 (Europe). Visit the official Fluke website for additional support resources, including online manuals and troubleshooting guides. Ensure to have your product details ready for efficient service.

9.3 Accessing Online Resources and Updates

Visit the official Fluke website at http://us.fluke.com/usen/support/manuals to access the latest manuals, FAQs, and software updates for the Fluke 117. Online resources include troubleshooting guides, technical specifications, and user forums to ensure optimal performance and troubleshooting of your multimeter.

The Fluke 117 is a durable, precise, and feature-rich multimeter ideal for electricians, offering advanced functions like non-contact voltage detection and true-RMS measurement for reliable results.

10.1 Summary of Key Features

The Fluke 117 is a true-RMS multimeter with non-contact voltage detection, Auto Volts, and LoZ functions. It features a 6000-count display, CAT III 600V safety rating, 10A current range, and frequency measurement (models 115 & 117). Designed for electricians, it ensures accurate and reliable results in demanding environments.

10.2 Final Tips for Optimal Usage

For optimal performance, always use proper terminals and ranges. Regularly check leads and ensure battery health. Store the multimeter in a dry, cool place, and refer to the manual for calibration and maintenance. This ensures accurate measurements and extends the life of your Fluke 117.